DHCM419W Request-to-Exit Sensor

CM-419 Series Request-to-Exit Sensors are designed for applications involving coverage at the threshold of a doorway. They can be combined with a card access system to shunt out the alarm system. Varied field
selectable options make it a compatible choice for mag lock / door strike release and alarm system shunting.

REX-sensor

  • 12/24V DC (Non Polarity) / 12 to 24V AC (50HZ / 60 HZ)
  • 40M A or less DC / 70M A or Less AC
  • Contact Type:(2) Form ‘C’
  • 1 Amp @ 30 VDC, 0.6 AMP @ 24VAC
  • Adjustable 0.25 to 60 seconds
  • Green Operation: Synchronous Dry / Contact Relay (LED) Disabled
  • +14°F to + 122°F
  • 6 5/15” x 2 3/8“ x 1 9/16”
  • White
  • Features:
    • – Dual pyroelectric sensors for increased stability
    • – Ceiling, wall or frame mount
    • – Adjustable coverage for single and double doors
    • – 0.25 to 60 second programmable output relay hold time
    • – Excellent immunity to RFI and other electrical noise
    • – 35° detection coverage
    • – Fail safe – fail secure operation
  • 3 year warranty